In a previous work we investigated the effectiveness of combining the concentration effects generated by a dual-pitched roof and a convergent-divergent semi-diffuser placed over a cross flow turbine (CFT), which is rooftop mounted with horizontal shaft running close to the roof ridge. By means of 2D CFD we now assess the effects of the upstream buildings on the performance of this concentration system. Three different urban layouts are simulated via a challenging fully-resolved URANS approach that gives unprecedented insight into the complex interactions of the flow around buildings, diffuser and turbine’s blades. A promising power augmentation of 40% with respect to the case without diffuser are obtained and the mechanism behind this performance enhancement are analysed. The beneficial effect of the diffuser on the torque fluctuations damping (~60%) is also discussed. Important remarks on the load control strategy for diffuser-augmented CFT are finally presented.

Effects of upstream buildings on the performance of a synergistic roof-and-diffuser augmentation system for cross flow wind turbines

STEFANIA ZANFORLIN
Primo
;
Stefano Letizia
Secondo
2019-01-01

Abstract

In a previous work we investigated the effectiveness of combining the concentration effects generated by a dual-pitched roof and a convergent-divergent semi-diffuser placed over a cross flow turbine (CFT), which is rooftop mounted with horizontal shaft running close to the roof ridge. By means of 2D CFD we now assess the effects of the upstream buildings on the performance of this concentration system. Three different urban layouts are simulated via a challenging fully-resolved URANS approach that gives unprecedented insight into the complex interactions of the flow around buildings, diffuser and turbine’s blades. A promising power augmentation of 40% with respect to the case without diffuser are obtained and the mechanism behind this performance enhancement are analysed. The beneficial effect of the diffuser on the torque fluctuations damping (~60%) is also discussed. Important remarks on the load control strategy for diffuser-augmented CFT are finally presented.
2019
Zanforlin, Stefania; Letizia, Stefano
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/961115
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? ND
social impact