Continuous electrocardiography (ECG) monitoring is the gold standard for diagnosing arrhythmias that occur intermittently or under exercise. The aim of this study was to compare two different methods for 24-hour Holter monitoring in horses, a 7-electrode system (7-ES) versus a 4-electrode system (4-ES), assessing the recording performance at rest and during exercise. Six standardbred horses were included in the present prospective study. Two different methods for 24-hour Holter monitoring were used in each horse with a washout period of one week between each recording method. In the first 15 minutes of the 24-hour Holter monitoring, a standard exercise test was performed. Holter recordings were analyzed in terms of the number of recorded hours; the number of detached electrodes (DEs); and total duration of artifacts over the 15-minute exercise. The number of recorded hours was significantly higher in the 7- ES (24 hours, range: 23e24 hours) than the 4-ES (6.5 hours, range: 1.2e20 hours; P < .05). The number of DEs was not significantly different between the two systems. The total duration of artifacts over the 15- minute exercise was significantly higher in the 7-ES (155 seconds, range: 35e378 seconds) than in the 4- ES (25 seconds, range: 10e32 seconds; P < .05). Our results showed a better recording performance during exercise using the 4-ES because of the lower number of artifacts. The 7-ES showed a better performance in terms of recording duration. In conclusion, we suggest using the 4-ES for exercise tests and the 7-ES when a longer ECG recording at rest is required.
Two Methods for 24-hour Holter Monitoring in Horses: Evaluation of Recording Performance at Rest and During Exercise
Tommaso VezzosiPrimo
;Micaela Sgorbini;Rosalba Tognetti
;Francesca BonelliUltimo
2019-01-01
Abstract
Continuous electrocardiography (ECG) monitoring is the gold standard for diagnosing arrhythmias that occur intermittently or under exercise. The aim of this study was to compare two different methods for 24-hour Holter monitoring in horses, a 7-electrode system (7-ES) versus a 4-electrode system (4-ES), assessing the recording performance at rest and during exercise. Six standardbred horses were included in the present prospective study. Two different methods for 24-hour Holter monitoring were used in each horse with a washout period of one week between each recording method. In the first 15 minutes of the 24-hour Holter monitoring, a standard exercise test was performed. Holter recordings were analyzed in terms of the number of recorded hours; the number of detached electrodes (DEs); and total duration of artifacts over the 15-minute exercise. The number of recorded hours was significantly higher in the 7- ES (24 hours, range: 23e24 hours) than the 4-ES (6.5 hours, range: 1.2e20 hours; P < .05). The number of DEs was not significantly different between the two systems. The total duration of artifacts over the 15- minute exercise was significantly higher in the 7-ES (155 seconds, range: 35e378 seconds) than in the 4- ES (25 seconds, range: 10e32 seconds; P < .05). Our results showed a better recording performance during exercise using the 4-ES because of the lower number of artifacts. The 7-ES showed a better performance in terms of recording duration. In conclusion, we suggest using the 4-ES for exercise tests and the 7-ES when a longer ECG recording at rest is required.File | Dimensione | Formato | |
---|---|---|---|
Vezzosi et al - Submission JEVS - May23_19.pdf
accesso aperto
Tipologia:
Documento in Pre-print
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.31 MB
Formato
Adobe PDF
|
1.31 MB | Adobe PDF | Visualizza/Apri |
1-s2.0-S0737080619304319-main.pdf
solo utenti autorizzati
Tipologia:
Versione finale editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
610.31 kB
Formato
Adobe PDF
|
610.31 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.