Film thickness is the most important parameter of a lubricated contact. Its evaluation in a cam-follower contact is not easy due to the continuous variations of speed, load and geometry during the camshaft rotation. In this work, experimental apparatus with a system for film thickness and shape estimation using optical interferometry, is described. The basic principles of the interferometric techniques and the color spaces used to describe the color components of the fringes of the interference images are reported. Programs for calibration and image analysis, previously developed for point contacts, have been improved and specifically modified for line contacts. The essential steps of the calibration procedure are illustrated. Some experimental interference images obtained with both Hertzian and elastohydrodynamic lubricated cam-follower line contacts are analyzed. The results show program is capable of being used in very different conditions. The methodology developed seems to be promising for a quasi-automatic analysis of large numbers of interference images recorded during camshaft rotation.

Film thickness and shape evaluation in a cam-follower line contact with digital image processing

Ciulli E.
Primo
;
Pugliese G.
Secondo
;
FAZZOLARI, FRANCESCO
Ultimo
2019-01-01

Abstract

Film thickness is the most important parameter of a lubricated contact. Its evaluation in a cam-follower contact is not easy due to the continuous variations of speed, load and geometry during the camshaft rotation. In this work, experimental apparatus with a system for film thickness and shape estimation using optical interferometry, is described. The basic principles of the interferometric techniques and the color spaces used to describe the color components of the fringes of the interference images are reported. Programs for calibration and image analysis, previously developed for point contacts, have been improved and specifically modified for line contacts. The essential steps of the calibration procedure are illustrated. Some experimental interference images obtained with both Hertzian and elastohydrodynamic lubricated cam-follower line contacts are analyzed. The results show program is capable of being used in very different conditions. The methodology developed seems to be promising for a quasi-automatic analysis of large numbers of interference images recorded during camshaft rotation.
2019
Ciulli, E.; Pugliese, G.; Fazzolari, Francesco
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/999100
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 11
social impact