The CP -violating weak phase ϕs and the decay width difference ΔΓs between the light and heavy Bs0 mass eigenstates are measured with the CMS detector at the LHC in a sample of 48500 reconstructed Bs0→J/ψϕ(1020)→μ+μ−K+K− events. The measurement is based on a data sample corresponding to an integrated luminosity of 96.4fb−1, collected in proton-proton collisions at s=13TeV in 2017–2018. To extract the values of ϕs and ΔΓs, a time-dependent and flavor-tagged angular analysis of the μ+μ−K+K− final state is performed. The analysis employs a dedicated tagging trigger and a novel opposite-side muon flavor tagger based on machine learning techniques. The measurement yields ϕs=−11±50(stat)±10(syst)mrad and ΔΓs=0.114±0.014(stat)±0.007(syst)ps−1, in agreement with the standard model predictions. When combined with the previous CMS measurement at s=8TeV, the following values are obtained: ϕs=−21±44(stat)±10(syst)mrad, ΔΓs=0.1032±0.0095(stat)±0.0048(syst)ps−1, a significant improvement over the 8 TeV result.
Measurement of the CP-violating phase ϕs in the Bs0→J/ψϕ(1020)→μ+μ−K+K− channel in proton-proton collisions at √s=13TeV
Asenov P.;Bianchini L.;Ciocci M. A.;Messineo A.;Rizzi A.;Tonelli G.;Cipriani M.;Marini A. C.;
2021-01-01
Abstract
The CP -violating weak phase ϕs and the decay width difference ΔΓs between the light and heavy Bs0 mass eigenstates are measured with the CMS detector at the LHC in a sample of 48500 reconstructed Bs0→J/ψϕ(1020)→μ+μ−K+K− events. The measurement is based on a data sample corresponding to an integrated luminosity of 96.4fb−1, collected in proton-proton collisions at s=13TeV in 2017–2018. To extract the values of ϕs and ΔΓs, a time-dependent and flavor-tagged angular analysis of the μ+μ−K+K− final state is performed. The analysis employs a dedicated tagging trigger and a novel opposite-side muon flavor tagger based on machine learning techniques. The measurement yields ϕs=−11±50(stat)±10(syst)mrad and ΔΓs=0.114±0.014(stat)±0.007(syst)ps−1, in agreement with the standard model predictions. When combined with the previous CMS measurement at s=8TeV, the following values are obtained: ϕs=−21±44(stat)±10(syst)mrad, ΔΓs=0.1032±0.0095(stat)±0.0048(syst)ps−1, a significant improvement over the 8 TeV result.File | Dimensione | Formato | |
---|---|---|---|
PhysLetB_816_136188.pdf
accesso aperto
Tipologia:
Versione finale editoriale
Licenza:
Creative commons
Dimensione
984.11 kB
Formato
Adobe PDF
|
984.11 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.