Dielectric characterization is extremely promising in medical contexts because it offers insights into the electromagnetic properties of biological tissues for the diagnosis of tumor diseases. This study introduces a promising approach to improve accuracy in the dielectric characterization of millimeter-sized biopsies based on the use of a customized electromagnetic characterization system by adopting a coated open-ended coaxial probe. Our approach aims to accelerate biopsy analysis without sample manipulation. Through comprehensive numerical simulations and experiments, we evaluated the effectiveness of a metal-coating system in comparison to a dielectric coating with the aim for replicating a real scenario: the use of a needle biopsy core with the tissue inside. The numerical analyses highlighted a substantial improvement in the reconstruction of the dielectric properties, particularly in managing the electric field distribution and mitigating fringing field effects. Experimental validation using bovine liver samples revealed highly accurate measurements, particularly in the real part of the permittivity, showing errors lower than 1% compared to the existing literature data. These results represent a significant advancement for the dielectric characterization of biopsy specimens in a rapid, precise, and non-invasive manner. This study underscores the robustness and reliability of our innovative approach, demonstrating the convergence of numerical analyses and empirical validation.
Open-Ended Coaxial Probe for Effective Reconstruction of Biopsy-Excised Tissues’ Dielectric Properties
Eliana Canicattì
;Nunzia Fontana;Sami Barmada;Agostino Monorchio
2024-01-01
Abstract
Dielectric characterization is extremely promising in medical contexts because it offers insights into the electromagnetic properties of biological tissues for the diagnosis of tumor diseases. This study introduces a promising approach to improve accuracy in the dielectric characterization of millimeter-sized biopsies based on the use of a customized electromagnetic characterization system by adopting a coated open-ended coaxial probe. Our approach aims to accelerate biopsy analysis without sample manipulation. Through comprehensive numerical simulations and experiments, we evaluated the effectiveness of a metal-coating system in comparison to a dielectric coating with the aim for replicating a real scenario: the use of a needle biopsy core with the tissue inside. The numerical analyses highlighted a substantial improvement in the reconstruction of the dielectric properties, particularly in managing the electric field distribution and mitigating fringing field effects. Experimental validation using bovine liver samples revealed highly accurate measurements, particularly in the real part of the permittivity, showing errors lower than 1% compared to the existing literature data. These results represent a significant advancement for the dielectric characterization of biopsy specimens in a rapid, precise, and non-invasive manner. This study underscores the robustness and reliability of our innovative approach, demonstrating the convergence of numerical analyses and empirical validation.File | Dimensione | Formato | |
---|---|---|---|
sensors-24-02160.pdf
accesso aperto
Tipologia:
Versione finale editoriale
Licenza:
Creative commons
Dimensione
5.95 MB
Formato
Adobe PDF
|
5.95 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.