Whole-room indirect calorimeters (WRIC) are accurate tools to precisely measure energy metabolism in humans via calculation of oxygen consumption and carbon dioxide production. Yet, overall accuracy of metabolic measurements relies on the validity of the theoretical model for gas exchange inside the WRIC volume in addition to experimental and environmental conditions that contribute to the uncertainty of WRIC outcome variables. The aim of this study was to quantitatively study the static sensitivity of a WRIC operated in a push configuration and located at the laboratories of the University Hospital of Pisa with the goal to identify the experimental conditions required to reach the best degree of accuracy for outcome metabolic measurements. Herein we demonstrate that achieving a fractional concentration of carbon dioxide inside the WRIC>0.2% at the steady state conditions allows to obtain a relative uncertainty <5% for the outcome metabolic measurements

Static sensitivity of whole-room indirect calorimeters

Bandini, Gabriele;Landi, Alberto;Santini, Ferruccio;Basolo, Alessio;Marracci, Mirko;Piaggi, Paolo
Ultimo
2022-01-01

Abstract

Whole-room indirect calorimeters (WRIC) are accurate tools to precisely measure energy metabolism in humans via calculation of oxygen consumption and carbon dioxide production. Yet, overall accuracy of metabolic measurements relies on the validity of the theoretical model for gas exchange inside the WRIC volume in addition to experimental and environmental conditions that contribute to the uncertainty of WRIC outcome variables. The aim of this study was to quantitatively study the static sensitivity of a WRIC operated in a push configuration and located at the laboratories of the University Hospital of Pisa with the goal to identify the experimental conditions required to reach the best degree of accuracy for outcome metabolic measurements. Herein we demonstrate that achieving a fractional concentration of carbon dioxide inside the WRIC>0.2% at the steady state conditions allows to obtain a relative uncertainty <5% for the outcome metabolic measurements
2022
978-1-6654-8299-8
File in questo prodotto:
File Dimensione Formato  
Bandini (2022 IEEE MeMea) static sens WRIC.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - accesso privato/ristretto
Dimensione 3.08 MB
Formato Adobe PDF
3.08 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
MeMeA_Stati_Sens_final_GB2_PP3.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.54 MB
Formato Adobe PDF
2.54 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1150919
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact