Whole-room indirect calorimeters (WRIC) are accurate tools to precisely measure energy metabolism in humans via calculation of oxygen consumption and carbon dioxide production. Yet, overall accuracy of metabolic measurements relies on the validity of the theoretical model for gas exchange inside the WRIC volume in addition to experimental and environmental conditions that contribute to the uncertainty of WRIC outcome variables. The aim of this study was to quantitatively study the static sensitivity of a WRIC operated in a push configuration and located at the laboratories of the University Hospital of Pisa with the goal to identify the experimental conditions required to reach the best degree of accuracy for outcome metabolic measurements. Herein we demonstrate that achieving a fractional concentration of carbon dioxide inside the WRIC>0.2% at the steady state conditions allows to obtain a relative uncertainty <5% for the outcome metabolic measurements
Static sensitivity of whole-room indirect calorimeters
Bandini, Gabriele;Landi, Alberto;Santini, Ferruccio;Basolo, Alessio;Marracci, Mirko;Piaggi, PaoloUltimo
2022-01-01
Abstract
Whole-room indirect calorimeters (WRIC) are accurate tools to precisely measure energy metabolism in humans via calculation of oxygen consumption and carbon dioxide production. Yet, overall accuracy of metabolic measurements relies on the validity of the theoretical model for gas exchange inside the WRIC volume in addition to experimental and environmental conditions that contribute to the uncertainty of WRIC outcome variables. The aim of this study was to quantitatively study the static sensitivity of a WRIC operated in a push configuration and located at the laboratories of the University Hospital of Pisa with the goal to identify the experimental conditions required to reach the best degree of accuracy for outcome metabolic measurements. Herein we demonstrate that achieving a fractional concentration of carbon dioxide inside the WRIC>0.2% at the steady state conditions allows to obtain a relative uncertainty <5% for the outcome metabolic measurementsFile | Dimensione | Formato | |
---|---|---|---|
Bandini (2022 IEEE MeMea) static sens WRIC.pdf
solo utenti autorizzati
Tipologia:
Versione finale editoriale
Licenza:
NON PUBBLICO - accesso privato/ristretto
Dimensione
3.08 MB
Formato
Adobe PDF
|
3.08 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
MeMeA_Stati_Sens_final_GB2_PP3.pdf
accesso aperto
Tipologia:
Documento in Post-print
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
2.54 MB
Formato
Adobe PDF
|
2.54 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.