This study introduces an innovative design for a Variable Stiffness 3 Degrees of Freedom actuated wrist capable of actively and continuously adjusting its overall stiffness by modulating the active length of non-linear elastic elements. This modulation is akin to human muscular cocontraction and is achieved using only four motors. The mechanical configuration employed results in a compact and lightweight device with anthropomorphic characteristics, making it potentially suitable for applications such as prosthetics and humanoid robotics. This design aims to enhance performance in dynamic tasks, improve task adaptability, and ensure safety during interactions with both people and objects. The paper details the first hardware implementation of the proposed design, providing insights into the theoretical model, mechanical and electronic components, as well as the control architecture. System performance is assessed using a motion capture system. The results demonstrate that the prototype offers a broad range of motion ([55, −45]° for flexion/extension, ±48° for radial/ulnar deviation, and ±180° for pronation/supination) while having the capability to triple its stiffness. Furthermore, following proper calibration, the wrist posture can be reconstructed through multivariate linear regression using rotational encoders and the forward kinematic model. This reconstruction achieves an average Root Mean Square Error of 6.6°, with an R2 value of 0.93.

Modeling and Control of a Novel Variable Stiffness Three DoFs Wrist

Catalano M. G.
Secondo
;
Bicchi A.
Penultimo
;
Grioli G.
Ultimo
2024-01-01

Abstract

This study introduces an innovative design for a Variable Stiffness 3 Degrees of Freedom actuated wrist capable of actively and continuously adjusting its overall stiffness by modulating the active length of non-linear elastic elements. This modulation is akin to human muscular cocontraction and is achieved using only four motors. The mechanical configuration employed results in a compact and lightweight device with anthropomorphic characteristics, making it potentially suitable for applications such as prosthetics and humanoid robotics. This design aims to enhance performance in dynamic tasks, improve task adaptability, and ensure safety during interactions with both people and objects. The paper details the first hardware implementation of the proposed design, providing insights into the theoretical model, mechanical and electronic components, as well as the control architecture. System performance is assessed using a motion capture system. The results demonstrate that the prototype offers a broad range of motion ([55, −45]° for flexion/extension, ±48° for radial/ulnar deviation, and ±180° for pronation/supination) while having the capability to triple its stiffness. Furthermore, following proper calibration, the wrist posture can be reconstructed through multivariate linear regression using rotational encoders and the forward kinematic model. This reconstruction achieves an average Root Mean Square Error of 6.6°, with an R2 value of 0.93.
2024
Milazzo, G.; Catalano, M. G.; Bicchi, A.; Grioli, G.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1241516
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact