In this work, we reported the application and validation of an improved high-performance liquid chromatography method coupled with a fluorimetric detector (HPLC-FL) to screen the activity of two heterocyclic derivatives reported as serine palmitoyl transferase (SPT) inhibitors. The analytical conditions were optimized in terms of the derivatization procedure, chromatographic condition, extraction procedure, and method validation according to EMEA guidelines. Once fully optimized, the method was applied to assess the SPT-inhibitory activity of the above-mentioned derivatives and of the reference inhibitor myriocin. The obtained results, expressed as a percentage of residual SPT activity, were compared to those obtained with the reference radio immune assay (RIA). The good correlation between the two types of assay demonstrated that the improved HPLC-FL method is suitable for a preliminary and rapid screening of potential SPT-inhibitors.

Application of An Improved HPLC-FL Method to Screen Serine Palmitoyl Transferase Inhibitors

BERTINI, SIMONE
Primo
;
SACCOMANNI, GIUSEPPE;DIGIACOMO, MARIA;GARGINI, MARIA CLAUDIA;PIANO, ILARIA;MACCHIA, MARCO;MANERA, CLEMENTINA
Ultimo
2017-01-01

Abstract

In this work, we reported the application and validation of an improved high-performance liquid chromatography method coupled with a fluorimetric detector (HPLC-FL) to screen the activity of two heterocyclic derivatives reported as serine palmitoyl transferase (SPT) inhibitors. The analytical conditions were optimized in terms of the derivatization procedure, chromatographic condition, extraction procedure, and method validation according to EMEA guidelines. Once fully optimized, the method was applied to assess the SPT-inhibitory activity of the above-mentioned derivatives and of the reference inhibitor myriocin. The obtained results, expressed as a percentage of residual SPT activity, were compared to those obtained with the reference radio immune assay (RIA). The good correlation between the two types of assay demonstrated that the improved HPLC-FL method is suitable for a preliminary and rapid screening of potential SPT-inhibitors.
2017
Bertini, Simone; Saccomanni, Giuseppe; Carlo, Sara Del; Digiacomo, Maria; Gargini, MARIA CLAUDIA; Piano, Ilaria; Campisi, Giuseppe Matteo; Ghidoni, Ri...espandi
File in questo prodotto:
File Dimensione Formato  
molecules-22-01198.pdf

accesso aperto

Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 3.02 MB
Formato Adobe PDF
3.02 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/876789
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact