The number of studies about ultrashort cardiovascular time series is increasing because of the demand for mobile applications in telemedicine and e-health monitoring. However, the current literature still needs a proper validation of heartbeat nonlinear dynamics assessment from ultrashort time series. This paper reports on the reliability of the Lagged Poincaré Plot (LPP) parameters - calculated from ultrashort cardiovascular time series. Reliability is studied on simulated as well as on real RR series. Simulated RR series are generated and LPP parameters estimated for ultrashort time series (from 15 to 60 s) are compared to those estimated from 1 h. All LPP parameters estimated from time series longer than 35 s presented a Spearman's correlation coefficient higher than 0.99. RR series acquired from 32 healthy subjects during 5-min resting state sessions are used to test the LPP approach in experimental data. The usefulness of ultrashort term parameters in real data is accomplished also studying their ability to discriminate positive and negative valence of auditory stimuli taken from the International Affective Digitized Sound System (IADS) dataset. The achieved accuracies in the recognition of elicitation along the valence dimension, using only the LPP parameters, were of 77.78% for 1 min 28 s series, and of 79.17% for 35 s series.
Reliability of lagged poincaré plot parameters in ultrashort heart rate variability series: Application on affective sounds
Nardelli, Mimma;Greco, Alberto;Valenza, Gaetano;Scilingo, Enzo Pasquale;
2018-01-01
Abstract
The number of studies about ultrashort cardiovascular time series is increasing because of the demand for mobile applications in telemedicine and e-health monitoring. However, the current literature still needs a proper validation of heartbeat nonlinear dynamics assessment from ultrashort time series. This paper reports on the reliability of the Lagged Poincaré Plot (LPP) parameters - calculated from ultrashort cardiovascular time series. Reliability is studied on simulated as well as on real RR series. Simulated RR series are generated and LPP parameters estimated for ultrashort time series (from 15 to 60 s) are compared to those estimated from 1 h. All LPP parameters estimated from time series longer than 35 s presented a Spearman's correlation coefficient higher than 0.99. RR series acquired from 32 healthy subjects during 5-min resting state sessions are used to test the LPP approach in experimental data. The usefulness of ultrashort term parameters in real data is accomplished also studying their ability to discriminate positive and negative valence of auditory stimuli taken from the International Affective Digitized Sound System (IADS) dataset. The achieved accuracies in the recognition of elicitation along the valence dimension, using only the LPP parameters, were of 77.78% for 1 min 28 s series, and of 79.17% for 35 s series.File | Dimensione | Formato | |
---|---|---|---|
paper_reliability_IEEE_rev2_rb2.pdf
accesso aperto
Tipologia:
Documento in Post-print
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.21 MB
Formato
Adobe PDF
|
1.21 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.